Ipandee Intelligent operation and maintenance platform
Ipandee Energy management system, providing round-the-clock real-time monitoring of operation and maintenance data
Service Hotline
Hotline:0755-23091101
Email:service@ipandee.com “7X24”
Waiting for customer service, quick response to solve your problem
Frequently Asked Questions
Guide for equipment installation and common fault handling
Company Profile
Obtain the qualification certificate and corporate album of Ipandee Enterprise
Product documentation
Obtain user manuals, installation and upgrade guides, configuration and tuning documents, acceptance and operation and maintenance instructions
Software Download
Download/upgrade relevant product computer software and APP software

Recommendations for off-grid system configuration schemes

lighting parameters

Average sunshine duration  hour(Please inquire about the average sunshine duration in your local area)

load parameter

load power  W Daily working hours of the load Load requirement for continuous rainy days  天 Number of days between consecutive rainy days  day

battery parameters

battery voltage  V         Depth of Discharge  %

inverter parameters

Conversion efficiency (provided to the manufacturer)  % Maximum power for long-term use under load / rated power of inverter (user requirements)  %

MPPT controller

Conversion efficiency (provided to the manufacturer)  % Input solar panel power/MPPT controller rated power (user requirements)  %

System

Daily power generation required to meet load demand  WH
Total power of solar panel  W
Standard voltage  V capacity  AH Can be fully charged (without load)  day Sustainable work  day
Inverter DC input  V Rated power at least  W
MPPT controller configuration  V Rated current at least  A

Recommended methods for connecting solar panels in series and parallel

solar panel

total rated power  W Estimated matching ratio     % Total power of solar panels required  W

Single solar panel

rated power      W Single-cell Voc voltage  V Single Vmpp voltage  V

battery bank

cell voltage      V series quantity        section Rated voltage of battery pack  V

MPPT controller

Maximum allowable input voltage  V

System

Number of solar panels required  block
series connections: Minimum number  skewer number of parallel connections  and Actual demand for solar panels  block Actual solar panel ratio  %
Refer series connections:Maximum number  skewer number of parallel connections  and Actual demand for solar panels  block  %
Suggested scheme for the number:Suggested number of series connections  skewer Suggested parallel connection quantity  and Actual demand for solar panels  block Actual solar panel ratio  %
1. The calculated result is an invalid solution. Please re-enter the correct parameters。
2. The above data is for reference only。